SOURce:SCENario:POWer[n]
Function
Sets the absolute power of channel or switch power ON or OFF when the scenario is running.
The parameter n, the channel number, can be:
- 1-5 for GSG-52/53
- 1-8 for GSG-54
- 1-16 for GSG-55/56
- 1-32/48/64 for GSG-62/63/64.
The freqband parameter is optional and can be used when only a certain satellite frequency band power is changed.
The value ALL in freqband means that the power for all bands is adjusted by the amount indicated via the command.
The command also accepts ON/OFF keywords as an argument, see examples below.
Command Syntax
SOURce:SCENario:POWer[n] <decimal>[,<freqband>]
SOURce:SCENario:POWer[n] ON|OFF
Note
Only available during scenario execution.
Parameters
Decimal [-160.0,-65.0] dBm, if freqband is not ALL. For ALL, the relative change by which the power setting is to be modified, should be limited to a delta of 100 (e.g., changing a power of -65 dBm to -165 dBm (by -100) and vice versa (+100).
FreqBand [L1, L2, L5, ALL]
Examples
SOURce:SCENario:POWer3 -75, ALL
- Set absolute power to -75 dBm for all channel #3 freqbands
SOURce:SCENario:POWer3 -115, L1
- Set absolute power to -115 dBm for the L1 channel #3 freqband
SOUR:SCEN:POW2 OFF
- Turns OFF power for channel #2
SOUR:SCEN:POW3 ON
- Turns ON power for channel #3, absolute power restored to the level it had before switching power off